Call a professional fire protection company-they will be able to fix your system and ensure that your building remains safe and up to code.AUDITS AND SURVEYS - We evaluate existing fire protection systems in order to determine deficiencies, minimize fire safety losses and assure property protection.īID AND CONSTRUCTION DOCUMENTS - we provide a vast array of documents depending upon client requirements. If your fire sprinkler system is ever damaged or requires repair, regular maintenance should not be your solution. Valves – the sprinkler valves should be internally inspected every five years.If your sprinkler heads are “fast response,” they should be replaced every 20 years. Sprinkler heads – these should be replaced every 50 years.
Gauges – gauges should be replaced or tested every five years by a licensed fire sprinkler technician to determine the calibration.There are other components of your fire sprinkler system that require certain maintenance and replacement at different intervals: Other Frequencies for Sprinkler Systems Maintenance If you own a building in the Houston, Texas area and need to schedule your annual fire sprinkler inspection, call the experts at Kauffman Co. They will also check for any necessary repairs or obstructions that would prevent the system from protection your building’s life and property in the event of a fire emergency. The technician will inspect and maintain all components of your fire sprinkler system, including:
The NFPA requires that you have a licensed technician inspect your fire sprinkler system annually to keep your building safe and up to code.
#Fire sprinkler system design checklist free
Alarm devices – every three months, check that these are free from physical damage.Quarterly Inspection Checklist for Sprinkler Systems Alarm valves – these should be externally inspected each month.Gauges (on wet pipe systems) – you should check that the water pressure is maintained and that there is no sign of physical damage.Monthly Inspection Checklist for Sprinkler Systems Proper signage should identify what part of your sprinkler they control. Control valves – you should check these weekly to ensure that they are free from leaks, locked, properly sealed, and in the open position.In this step, you’re looking for a normal read on air and water pressure. Gauges – the gauges on dry, pre-action, and deluge systems should be inspected weekly.Weekly Inspection Checklist for Sprinkler Systems If you ever have concerns or questions about fire sprinkler maintenance or inspection, you should contact a local licensed fire protection company. Below, we‘ve provided a breakdown of maintenance steps you should take with your fire sprinkler systems. If you’re looking for a maintenance or inspection checklist for your fire sprinkler, look no further. When it comes to your fire sprinkler system, the NFPA 25 is the standard for inspection, testing, and maintenance of water-based fire protection systems and “compliance helps maximize integrity to avoid failure and ensure fast, effective response in a fire emergency.” The National Fire Protection Association (NFPA) sets the standards for fire protection systems and measures in commercial buildings. Fire Sprinkler System Maintenance Checklist